SKZ111L-5 110g /0.005g 5mg electronic halogen moisture analyzer reliable performance novel appearance
Quick (1-6 minutes) Determination of moisture of the measured object, using the principle of heating and drying, moisture values
measured object is automatically displayed, the data is stable and accurate.
Measurement: powder form, granular, paste, liquid, organic and inorganic chemical raw materials, a variety of cereals, grain,
seed, feed, starch, food, meat, tobacco, tea, paper, grass, soil, sludge , textiles, fuel, resin, silica, plastic particles, coal,
fertilizer, medicine, ceramics, wood, ore.
measured object is automatically displayed, the data is stable and accurate.
Measurement: powder form, granular, paste, liquid, organic and inorganic chemical raw materials, a variety of cereals, grain,
seed, feed, starch, food, meat, tobacco, tea, paper, grass, soil, sludge , textiles, fuel, resin, silica, plastic particles, coal,
fertilizer, medicine, ceramics, wood, ore.
Features:
1. High accuracy: halogen moisture analyzer with fast and sensitive load cell.
2. Standard RS-232 interface: connect a PC or a printer.
3. Easy to operate: ergonomically designed handle plate, to avoid burns hot when placed in a sample taken, wing-shaped handle
easily turned off heated lid.
4. Three kinds of drying process
1). Standard Drying: The default setting, Suitable for most samples. The heating temperature can be set, the sample is heated to
the set temperature, and remains on until test is automatically terminated.
2). Slow Drying: For sample with lower moisture content, easy to form the shell surface, flammable. It takes long time from i
nitial heating temperature to a set value, User can select the heating time.
3). Fast drying: Suitable for higher moisture content samples. Can be set the heating temperature, Initial heating temperature
exceeds a set value, Would later reduced to a set temperature and maintained until the test is automatically terminated.
5. Three shutdown mode: Automatic shutdown, manual shutdown, timed shutdown
6. Can be equipped with printer (with extra charge)
7. Provided 100g poise for calibration
1. High accuracy: halogen moisture analyzer with fast and sensitive load cell.
2. Standard RS-232 interface: connect a PC or a printer.
3. Easy to operate: ergonomically designed handle plate, to avoid burns hot when placed in a sample taken, wing-shaped handle
easily turned off heated lid.
4. Three kinds of drying process
1). Standard Drying: The default setting, Suitable for most samples. The heating temperature can be set, the sample is heated to
the set temperature, and remains on until test is automatically terminated.
2). Slow Drying: For sample with lower moisture content, easy to form the shell surface, flammable. It takes long time from i
nitial heating temperature to a set value, User can select the heating time.
3). Fast drying: Suitable for higher moisture content samples. Can be set the heating temperature, Initial heating temperature
exceeds a set value, Would later reduced to a set temperature and maintained until the test is automatically terminated.
5. Three shutdown mode: Automatic shutdown, manual shutdown, timed shutdown
6. Can be equipped with printer (with extra charge)
7. Provided 100g poise for calibration
Technical parameters
Model
|
SKZ111L-10
|
SKZ111L-5
|
SKZ111L-2
|
SKZ111L-1
|
|||
Specification
|
110g/10mg
|
110g/5mg
|
110g/2mg
|
110g/1mg
|
|||
Readability
|
10mg
|
5mg
|
2mg
|
1mg
|
|||
Moisture range
|
0.0%-100%
|
0.00%—100%
|
|||||
Moisture Readability accuracy
|
0.2%
|
0.1%
|
0.04%
|
0.01%
|
|||
Dry residual range
|
100.00%—0.00%
|
||||||
Dry residual Readability accuracy
|
0.2%
|
0.1%
|
0.04%
|
0.01%
|
|||
Pan size
|
Φ 90mm
|
||||||
Heating mode
|
Halogen lamp
|
||||||
Display
|
LCD
|
||||||
Temperature sensor
|
PT-100
|
||||||
Temperature Setting
|
40℃~199℃
|
||||||
Temperature interval
|
1°C
|
||||||
Working temperature
|
5°C—35°C
|
||||||
Time Setting
|
1~99 minutes
|
||||||
Automatic shutdown
|
0.1%—9.9%within 1 min
|
||||||
ATRO
|
100%~999%
|
||||||
ATRO
|
0%~999%
|
||||||
History store
|
15 groups
|
||||||
Power supply
|
220V
|
||||||
Heater
|
220V+15%50Hz, 115V+15%, 400W
|
||||||
Balance
|
External power, Output: 9V, input: 220V+15%, 50Hz
|
||||||
Calibration mode
|
External calibration with provided poise 100g
|
||||||
Connect output
|
RS232
|
||||||
Dimensions(W*L*H)
|
200*180*380mm
|
||||||
Weight
|
6kg
|
||||||
Optional with extra charge
|
Printer, moisture regain (R)
|
Avis
Il n’y a pas encore d’avis.